Panasonic A6 AC Servo Motor System Configuration and Wiring -- 2.2.2 Overall Wiring

HIGH SPEED IML ROBOT

Keywords:Panasonic A6 Servo Motor, Panasonic A6 Servo Motor Driver, Panasonic A6 Servo Motor setting instruction

Panasonic A6 AC Servo Motor System Configuration and Wiring -- 2.2.2 Overall Wiring

Abstract

The correct wiring is the guarantee of safety of the Panasonic A6 series AC servo motor application, here in this chapter we'll introduce the correct wiring of the Panasonic A6 AC servo motor and driver in your machineries and automation system.

Connecting Example of A to B-frame
Panasonic A6

Related page → •P.2-14 "Wiring of the Main Circuit (A to B-frame, 100 V/200 V type)" •P.2-28 "Specifications of Motor connector"

A to B-frame, 100 V/200 V type
•Tips on Wiring
  1. Wire connector (XA and XB)
  2. Connect the wired connector to the driver. Fully insert the connector to the bottom until it clicks.
Panasonic A6

Note → The wiring indicated with the broken line shall be provided only when required.
Related page → •P. 2-28 "Specifications of Motor connector" •P.2-31 "Wiring method to connector" •P.7-132 "Connector kit fo XA" •P.7-133 "Connector kit for XB"

Compose the circuit so that the main circuit power will be shut off when an error occurs. However, if you want to use "immediate stop function" and the main circuit power turns off, please be aware that you will no longer be able to use "immediate stop function".

In Case of Single Phase, A to B-frame, 100 V/200 V type

Power supply Single phase, 100 V - 15% to 120 V +10%/200V - 15% to 240V + 10%

Panasonic A6
Panasonic A6
In Case of 3-Phase, A to B-frame, 200 V type

Power supply 3-phase, 200 V - 15% to 240V + 10%

Panasonic A6
Panasonic A6

Note.1)

Frame No. Short wire (Accessory) Built-in regenerative resistor Connection of the connector XB
In case of using an external regenerative resistor. In case of not using an external regenerative resistor.
A-frame
B-frame
without without • Connect an external regenerative resistor between P-B •Always open between P-B

Note → The wiring indicated with the broken line whall be provided only when required.
Related page → •P.2-28 "Specifications of Motor connector" •P.2-31 "Wiring method to connector"

Connecting Example of C to D-frame
Panasonic A6

Note → This overall wiring diagram is a typical one. The pages that follow show wiring for specific application. The wiring indicated with the broken line shall be provided only when required.
Related page → •P.7-108 ..."Options" •P.2-18 "Wiring of the Main Circuit (A to B-frame, 100 V/200 V type)" •P. 2-28 " Specifications of Motor connector"

C to D-frame, 100 V/200 V type

Note → The wiring indicated with the broken line shall be provided only when required.

Related page → •P.2-28 "Specifications of Motor connector" •P.2-31 "Wiring method to connector" •P.7-132 "Connector kit for XA" •P.7-133 "Connector kit for XB"

Connecting Example of E-frame
Panasonic A6

Note → This overall wiring diagram is a typical one. The pages that follow show wiring for specific application. The wiring indicated with the broken line shall be provided only when required.

Related page → •P.7-108... "Options" •P.2-18 "Wiring of the Main Circuit (E-frame, 200V type)" •P.2-28 "Specifications of Motor connector"

E-frame, 200 V type
Panasonic A6

Note → The wiring indicated with the broken line shall be provided only when required.
Related page → •P.2-28 "Specifications of Motor connector" •P.2-31 "Wiring method to connector" •P.7-132 "Connector kit for XA, XC" •P.7-133 "Connector kit for XB"
Compose the circuit so that the main circuit power will be shut off when an error occurs. However, if you want to us "immediate stop function" and the main circuit power turns off, please be aware that you will no longer be able tous "immediate stop function".

In Case of 3-Phase, E-frame, 200 V type

Power supply 3-phase, 200V -15 % to 240V +10%

Panasonic A6

Note.1)

Frame No. Short wire (Accessory) Built-in regenerative resistor Connection of the connector XC
In case of using an external regenerative resistor. In case of not using an external regenerative resistor.
E-frame with with
  • Remove the short wire accessory from between RB-B.
  • Connect an external regenerative resistor between P-B.
  • Shorted between RB-B with an attached short wire.


Note → The wiring indicated with the broken line shall be provided only when required.
Relalted page → &bullP.2-28 "Specifications of Motor connector" •P.2-31 "Wiring method to connector"

Connecting Example of F-frame
Panasonic A6

Note → This overall wiring diagrma is a typeical one. The pages that follow show wiring for specific application. The wiring indicated with the broken line shall be provided only when required.
Related page → •P.7-108... "Options" •P.2-26 "Wiring of the Main Circuit (F-frame, 200 V type)" •P.2-28 "Specifications of Motor connector"

F-frame, 200V type
Panasonic A6

Note → The wiring indicated with the broken line shall be provided only when required.
Related page → •P.2-28 "Specifications of Motor connector"
Compose the circuit so that the main circuit power will be shut off when an error occurs. However, if you want to use "immediate stop function" andd the main circuit power turns off, please be aware that you will no longer be able to use "immediate stop function".

In Case of 3-Phase, F-frame, 200V type

Power supply 3-phase, 200 V -15% to 230 V +10%

Panasonic A6

Note.1)

Frame No. Short bar (Accessory) Built-in regenerative resistor Connection of terminal block
In case of using an external regenerative resistor. In case of not using an external regenerative resistor.
F-frame with with
  • Remove the short bar accessory from between RB-B.
  • Connect an external regenerative resistor between P-B.
  • Shorted between RB-B with an attached short bar.


Note → The wiring indicated with the broken line shall be provided only when required.
Related page → •P.2-28 "Specifications of Motor connector"


Hybrid Injection Molding Machine for Laboratory Consumable Petri Dish Injection Molding -- HD300KDY
Haida hybrid Injection Molding Machine
HD300KDY

HD300KDY -- HaiDa Hybrid Injection Molding Machine

No. Name Value
1 Clamping Force 3000 kN
2 Shot Weight 402 g
3 Shot Speed 350 mm/s
4 Screw Diameter 50 mm
5 Opening Stroke 550 mm
6 Space Between Tie Bars 590 x 590 mm
7 Mold Thickness (Min) 220 mm
8 Mold Thickness (Max) 600 mm
9 Pumper Motor 147 kW
10 Heating Capacity 21 kW

Injection Automation Application -- Side Entry Petri Dishs Injection Molding Automation Solution
petri dish packing solution

SIDE ENTRY PETRI DISH PACKING SOLUTION

Introduction of SWITEK Side Entry Petri Dish Packing System

The SWITEK side entry petri dish packing system is a custom made automation system for the stable production of laboratory consumable plastic petri dish with the picking robot, the petri dish assembly, stacking, packing unit etc. integrated as auniformed system for the efficient and stable production of the petri dish. The system can be custome made for a petri dish mold layout design of 2+2, 4+4, 6+6, 8+8 etc.

Functional Units of SWITEK Top Entry Petri Dish Packing System
petri dish packing solution
  • (1) -- Side Entry Robotic Arm: The picking arm of the packing system in handling the picking of the petri dish from the injection molding machine and place them on the assembly unit.
  • (2) -- Injection Mold: The core injection unit to shape the petri dish, it can be 2+2, 4+4, 6+6, 8+8 configuragion of the petri covers and bottoms.
  • (3) -- Petri Dish Assembly Unit: Have the cover and bottom of the petri dish assembled and drop it on the conveyor.
  • (4) -- Sorting Conveyor: Lined the assembled petri dish sets for stacking before packing.
  • (5) -- Stacking Station: Have the well assembled petri dishes stacked up as requested (5/10/15/20/25 sets etc.).
  • (6) -- Petri Dish Packing Unit: Have the well stacked petri dish packed and sealed with optional function of vacuume the bag.
  • (7) -- Petri Dish Transfer Robot: Catch the well sealed petri dish bag and drop it to the conveyor.
  • (8) -- Petri Dish Dropping Conveyor: Deliver the well packed petri dish.
  • (9) -- Injection Molding Machine: The injection unit of the whole syste.

Installation Dimension of SWITEK Side Entry Petri Dish Packing System
petri dish packing solution

Productivity of SWITEK Side Entry Petri Dish Packing Solutions
    Vacuumed Sleeve Packing
  • 10 Sets/Bag --Injection Cycle time: 9s
  • 20 Sets/Bag --Injection cycle: 6s
  • 25 Sets/Bag --Injection Cycle: 5.5s
    Non-vacuumed Sleeve Packing
  • 10 Sets/Bag --Injection Cycle time: 6.5s
  • 20 Sets/Bag --Injection cycle: 6s
  • 25 Sets/Bag --Injection Cycle: 5.5s

Mold Layout Design & Sleeve Size for the Petri Dish Packing System
petri dish packing solution

Mold Layout Deisgn

petri dish packing solution

Sleeve Size for Package with Vacuum Request

petri dish packing solution

Sleeve Size for Package without Vacuum Request

petri dish packing solution

Sleeve (With Mark) Size for Package with Vacuum Request

petri dish packing solution

Sleeve (With Mark) Size for Package without Vacuum Request

I think you'll have an overall understanding about the SWITEK top/side entry petri dish packing system. If you still have any other question about it or need any help in your petri dish production project, please feel free to contact SWITEK laboratory consumable plastic parts injection molding solutions team for more information.


Email: sales06@switek.biz

WhatsApp

WeChat


Request for Quotation Now
Submit